Home > Industry Information > Antai ATG-2161 Power Signal Source Indicator Parameter Introduction
ATG-2161 Power Signal Introduction
External signal input terminal isBNC interface.When the signal is input built -in input, at this time, the power signal source mode, set the waveform, frequency, voltage and other parameters; when the signal is accessed, at this time is the amplifier mode, the input resistance is 5kΩ, the output resistance can be switched, the voltage gain adjustment voltage gain can be adjusted.You can implement signal amplification.
OutputOutput
The output interface is banana socket, output voltage0 ~ 1600VP-P (± 800VP), output current (peak) 40map.
LCD panel display
ATG-2161 power signal source operating panel liquid crystal display, device status and parameter dynamic display, the interactive interface is clear at a glance, simple and easy to understand.
The ATG-2161 power signal source is an amplifier working mode when the exterior input signal is input. At this time, the voltage gain is a CNC 0 to 240 times (1tep).Combined with the display of LCD panel gain, it can quickly adjust to the required voltage value.
Monitoring portMonitor
1/100MONITOR: This port voltage is 1/100 of the output port. The monitoring port is the BNC connector, which can be directly connected to the oscilloscope forOutput voltageReal -time monitoring.